Manual Routing
Route the following types of nets first:
- Most difficult
- Most complex
- Tight fitting nets first
- Very high current (primarily external)
- Very high voltage (primarily internal)
- Sensitive
- Noisy
- Separate analog and digital.
- Route busses.
Auto Routing
- Manually route those items shown in "manual routing" first, if necessary.
- Define attributes that are common only to the auto router.
- Define/select "Routine," "Do" file, "Route" file, or "Strategy" file.
After route completion:
- Manually clean up paths.
- Miter right angle corners.
- Run DRC/design rules to ensure clearances are met.
- Check annular ring.
- Change gates or parts.